Seeing an error code on your Samsung air source heat pump can be a little concerning, especially if your heating or hot water has stopped working.
But don’t panic. An error code doesn’t automatically mean your heat pump has developed a major fault. It simply means the system has detected something that needs attention.
Some issues relate to water circulation, others can involve sensors or communication between the different parts of the system. While there are a few basic things you can check yourself, some faults will need a qualified heat pump engineer to investigate.
If you’ve got a Samsung air source heat pump and have noticed an E101, E911, E912 or another error code on your controller, here’s what it could mean, what you should look out for and when it’s time to get an engineer involved.
Make a note of the error code
Before doing anything, make a note of exactly what your Samsung heat pump is displaying.
If possible, take a photograph of the controller. This can be really useful when speaking to your heating engineer, as it gives them a better idea of what’s happening before they visit.
It’s worth remembering that Samsung has several generations of air source heat pumps, and error codes can vary between models.
A fault code on an older system might not have exactly the same meaning on a newer model.
You should always check the fault against the correct Samsung manual for your particular unit.
And while resetting the system may clear some temporary errors, it won’t necessarily fix the underlying problem. If the same code keeps appearing, don’t keep resetting it and hoping for the best.
E101: Indoor and outdoor unit wiring error
An E101 error indicates a wiring connection problem between the indoor control kit and the outdoor unit on applicable Samsung EHS models.
Your heat pump relies on communication between its different components to operate correctly. If that connection is interrupted, the system may not be able to function as it should.
Possible causes include:
- A problem with the communication wiring.
- A loose or damaged electrical connection.
- An issue with one of the control boards.
- A communication problem following an electrical interruption.
If you’ve recently experienced a power cut or had electrical work carried out, it’s worth mentioning this when contacting your engineer.
There isn’t much to check yourself with this particular fault. The wiring and electrical connections need to be inspected by someone suitably qualified.
If the error remains on the controller, arrange for an engineer to investigate rather than attempting to access the electrical components yourself.
E911: Low water flow
An E911 error is one worth paying attention to.
On a number of Samsung EHS systems, this indicates that the heat pump has detected insufficient water flow while the circulation pump is operating.
In simple terms, your heat pump needs enough water moving around the heating circuit to transfer heat effectively. If the flow rate drops below the required level, the system can trigger a fault and stop operating.
There are several possible reasons for this, including:
- A blocked or restricted system filter.
- Air trapped within the heating circuit.
- A problem with the circulation pump.
- A valve that’s stuck or not opening correctly.
- Insufficient water flow through the system.
- A problem with the flow switch.
You can have a look around your heating system for any obvious leaks and check whether the controller is showing any other warnings.
However, diagnosing low water flow involves checking the heating circuit, filters, pump and flow switch.
If the E911 error keeps coming back, get an engineer to investigate. Simply resetting the system won’t resolve a restriction or circulation problem.
E912: Flow switch error
An E912 error relates to the flow switch detecting water movement when the circulation pump is supposed to be switched off.
The flow switch helps the heat pump monitor what’s happening within the water circuit, so an unexpected reading can cause the system to register a fault.
Possible causes can include:
- An issue with the flow switch.
- Incorrect flow switch installation.
- Unexpected water circulation.
- A problem with the circulation pump or associated controls.
This isn’t one we’d recommend trying to fix yourself.
An engineer will need to check the flow switch, pump operation and water circulation to establish why the system is detecting flow when it shouldn’t be.
If you’re seeing this error repeatedly, arrange for the system to be inspected rather than repeatedly resetting it.
E904: Hot water cylinder temperature sensor fault
An E904 error on applicable Samsung EHS systems indicates a problem with the domestic hot water cylinder temperature sensor.
This sensor monitors the temperature of the water stored in your hot water cylinder and helps the heat pump manage your hot water requirements.
If the sensor isn’t providing the correct information, the system may struggle to monitor or control the hot water temperature properly.
Possible causes include:
- A faulty temperature sensor.
- A loose or disconnected sensor connection.
- Damaged sensor wiring.
- A problem with the control board.
If you’ve noticed problems with your hot water alongside the error code, make a note of this when contacting your engineer.
The sensor and its connections will need to be checked to establish whether the issue is with the sensor itself or another part of the control system.
Avoid removing the cylinder covers or attempting to access electrical connections yourself.
E919: Hot water disinfection cycle incomplete
An E919 error relates to the hot water disinfection cycle not completing successfully on applicable Samsung EHS models.
Many heat pump systems have a scheduled hot water disinfection cycle, sometimes referred to as a legionella prevention cycle.
This helps raise the stored hot water temperature as part of the system’s hygiene programme.
If the required temperature isn’t reached within the allowed time, the system may register an E919 error.
Possible reasons include:
- An issue with the immersion heater.
- A problem with the hot water cylinder temperature sensor.
- The hot water temperature not reaching the required level.
- An issue with the hot water controls or settings.
If you notice this error, it’s worth checking whether you’ve also experienced problems with your hot water.
Don’t simply switch off the disinfection programme to clear the warning. The system needs to complete its intended hygiene cycle.
An engineer can check the cylinder sensor, immersion heater and associated controls to establish why the cycle hasn’t completed.
NEED YOUR HEAT PUMP SERVICED?
Choose a one-off heat pump service or join our Annual Heat Pump Service Plan and we’ll take care of it each year.